Abstract
Introduction: In COVID-19 associated hypoxemic acute respiratory failure (ARF) without mandatory indication for urgent endotracheal intubation, a trial of CPAP may be considered. We aimed to evaluate HACOR (heart rate, acidosis, consciousness, oxygenation, respiratory rate) score performance in these patients as predictor of CPAP failure.
Methods: Prospective observational multicentric study (three centers in different countries), including adult patients with SARS-CoV-2 pneumonia admitted to a respiratory intermediate care unit, presenting PaO 2 /FiO 2 < 300 and PaCO 2 < 45 mmHg, who received CPAP. One hour after starting CPAP, HACOR was calculated.
Results: We enrolled 128 patients, mean age 61,7 years. Mean HACOR at 1 h after starting CPAP was 3,27 ± 3,84 and mean PaO 2 /FiO 2 was 203,30 ± 92,21 mmHg; 35 patients (27,3 %) presented CPAP failure: 29 underwent oro-tracheal intubation and 6 died due to COVID-19 (all having a do-not-intubate order). HACOR accuracy for predicting CPAP failure was 82,03 %, while PaO 2 /FiO2 accuracy was 81,25 %.
Conclusion: Although HACOR score had a good diagnostic performance in predicting CPAP failure in COVID-19-related ARF, PaO 2 /FiO 2 has also shown to be a good predictor of failure.
Keywords: COVID-19; CPAP; HACOR score; Hypoxemic acute respiratory failure.
【저자키워드】 COVID-19, CPAP, HACOR score, Hypoxemic acute respiratory failure., Hypoxemic acute respiratory failure, 【초록키워드】 Respiratory failure, Trial, Pneumonia, diagnostic, intubation, Accuracy, Prospective, Patient, age, Care, patients, respiratory rate, Oxygenation, Endotracheal intubation, hypoxemic, enrolled, shown, evaluate, died, calculated, presenting, ARF, mandatory, PaO, patients with SARS-CoV-2, 【제목키워드】 Hypoxemia,