Objectives: Limitations of widespread current COVID-19 diagnostic testing exist in both the pre-analytical and analytical stages. To alleviate these limitations, we developed a universal saliva processing protocol (SalivaSTAT) that would enable an extraction-free RT-PCR test using commercially available RT-PCR kits. Methods: We optimized saliva collection devices, heat-shock treatment, and homogenization. Saliva samples (879) previously tested using the FDA-EUA method were reevaluated with the optimized SalivaSTAT protocol using two widely available commercial RT-PCR kits. A five-sample pooling strategy was evaluated as per FDA guidelines. Results: Saliva collection (done without any media) showed performance comparable to that of the FDA-EUA method. The SalivaSTAT protocol was optimized by incubating saliva samples at 95 °C for 30-min and homogenization, followed by RT-PCR assay. The clinical sample evaluation of 630 saliva samples using the SalivaSTAT protocol with PerkinElmer (600-samples) and CDC (30-samples) RT-PCR assay achieved positive (PPA) and negative percent agreements (NPAs) of 95.0% and 100%, respectively. The LoD was established as ~60–180 copies/mL by absolute quantification. Furthermore, a five-sample-pooling evaluation using 250 saliva samples achieved a PPA and NPA of 92% and 100%, respectively. Conclusion: We have optimized an extraction-free RT-PCR assay for saliva samples that demonstrates comparable performance to FDA-EUA assay (Extraction and RT-PCR).
【저자키워드】 Saliva, RT-PCR, pooling, extraction-free, 【초록키워드】 COVID-19, Treatment, protocol, diagnostic, media, FDA, CDC, quantification, RT-PCR assay, saliva sample, RT-PCR test, stages, extraction, limitation, positive, RT-PCR kits, limitations, widespread, PerkinElmer, homogenization, tested, evaluated, comparable, alleviate, 【제목키워드】 SARS-CoV-2, mass, setting, Sample,