Lateral flow immunoassays (LFIA) for detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies are used for population surveillance and potentially individual risk assessment. The performance of the SureScreen Diagnostics LFIA targeting the spike protein was evaluated in comparison with 3 automated assays (Abbott Alinity-i SARS-CoV-2 IgG, DiaSorin Liaison® SARS-CoV-2 S1/S2 IgG, Wantai SARS-CoV-2 Ab ELISA). We assessed sensitivity using 110 serum samples from PCR confirmed COVID-19 infected patients. Specificity was evaluated using 120 prepandemic samples, including potential cross-reactive antibodies samples. Sensitivity ranged between 93.3% and 98.7% on samples collected >14 days postsymptom onset. All assays achieved a specificity >98%. Moreover, its performance seems not to be affected by Alpha, Beta or Delta variants over a wide range of antibody titers. The latter showed a very good agreement with the Wantai and the Abbott assays and a substantial agreement with the DiaSorin assay. Our data demonstrate the good clinical performance of the SureScreen Diagnostics LFIA for SARS-CoV-2 seroprevalence screening.
【저자키워드】 COVID-19, SARS-CoV-2, serology, RBD, receptor-binding domain, ELISA, enzyme-linked immunosorbent assay, NTD, N-terminal domain, lateral flow immunoassays (LFIA), CMV, cytomegalovirus, EBV, Epstein-Barr virus, anti-N, anti-nucleocapsid, anti-S, anti-spike, LFIA, Lateral Flow Immunoassays, SureScreen Diagnostics,